What is suggested maintenance?

  • Replace lower end seal kit every 12 months.

What is maximum water temperature?

  • 104 degrees Fahrenheit.

What dilution rates are available? 

  • Dosatron offers three key ranges:
    • 1:3000 to 1:333
    • 1:500 to 1:50
    • 1:100 to 1:10

What should I do if the dilution rate seems to be drifting? 

  • Check the hose connection for air leaks.
  • Replace the seal kit.

What is the optimal water pressure?

  • Dosatron units are rated from 4.3 to 85 PSI and will work well within this range.

Can I foam chemical using a Dosatron?

  • Yes. Be sure to stabilize the water pressure supplying the Dosatron using a water pressure regulator or booster pump.

How long do Dosatron units last?

  • Dosatron units are engineered to last for years. We have seen units in service for over 10 years.

How do I check the dilution rate? 

  • Do a volume to volume test.