What is suggested maintenance?
- Replace lower end seal kit every 12 months.
What is maximum water temperature?
- 104 degrees Fahrenheit.
What dilution rates are available?
- Dosatron offers three key ranges:
- 1:3000 to 1:333
- 1:500 to 1:50
- 1:100 to 1:10
What should I do if the dilution rate seems to be drifting?
- Check the hose connection for air leaks.
- Replace the seal kit.
What is the optimal water pressure?
- Dosatron units are rated from 4.3 to 85 PSI and will work well within this range.
Can I foam chemical using a Dosatron?
- Yes. Be sure to stabilize the water pressure supplying the Dosatron using a water pressure regulator or booster pump.
How long do Dosatron units last?
- Dosatron units are engineered to last for years. We have seen units in service for over 10 years.
How do I check the dilution rate?
- Do a volume to volume test.