The purpose of this kit is to allow the CTA, FOAMING CTA, MAG WHEEL APPLICATOR, OMNI DIRECTIONAL CHANGE, to operate when no equipment programmer functions are available to actuate and maintain unit functions


The items included in the kit: 

  • Control Box with adjustable off-delay timer (0.1 - 10 seconds) and pre-wired socket. 

NOTE: Timer coil requires 110 VAC, single phase, 60 Hz power. 

  • Floor Switch for the timer initiate signal


INSTALLATION:

  1. Place the floor switch in position approximately 2 feet ahead of the equipment to be actuated
  2. See the electrical schematic included with these instructions for wiring connections. 
  3. This kit is wired for 110VAC, single phase, 60 Hz power.

NOTE: If 24VAC output operation is required REMOVE the jumper wire between timer socket pins #1 and #2. Then feed 24 VAC hot power to socket pin #1 for 24VAC output from pin #3 upon actuation

DO NOT APPLY VOLTAGE TO THE FLOOR SWITCH OR TIMER PINS #5 AND #6(See the electrical schematic below:






If you need further assistance please contact your Sonny's Technical Support Team at: SonnysSupport@SonnysDirect.com