Pendulum wheel blaster uses a high pressure pump to provide 600-800 PSI to the spinner nozzles. If the spinners are not spinning please check for the following: 

  • Make sure there is water flowing into the pump station tank
  • Make sure the regulator at the pump is set between 600-800 PSI
  • Check the nozzles for wear -- If the nozzles are worn it will cause a pressure drop in the system.  Change the nozzles and check the equipment for rotation
  • Replace the ceramic swivel


The tubes on the T-bar are bent.  When the pump is flowing water through the T-bar the pressure will make the bar spin.  


NOTE: Do not try to bend the bars straight, trying to do so will damage the bars.