Pivoting applicator arch pivots to track vehicles as they pass using pneumatic control for increased contact time and complete coverage at high chain speeds. Recommend for high-volume washes - Over 120CPH
If the manifolds are not pivoting check for the following:
- Make sure the compressor is on
- Make sure the lines on the mac valve are connected correctly.
- The mac valve has 5 ports
PORT 1 - AIR IN -- Connect your main airline to this port
PORT 2 - NC(Normally Closed) -- Connect this port to the back of the cylinder.
PORT 3 - NO(Normally Open) -- Connect this port to the front of the cylinder.
PORT 4 and 5 -- Exhaust ports for ports 2 and 3
- Test the mac valve by pushing the silver button. The manifold should pivot once the button has been pressed. If nothing happens replace the mac valve or coil only.
- Flip the toggle switch on the controller to manual. The manifold should pivot once the switch has been changed to manual. If nothing happens check the relay and/or fuse.
If you have any further questions, please feel free to contact your Sonny's Technical Support Team at: SonnysSupport@SonnysDirect.com