Is this a new install? 

With new installations it is usual for a piece of tie wrap or foreign object to enter the pump through the tank.  This object will cause the valves to stay open and cause the pump to run rough.  If this occurs do the following: 


  • Starting with the outside bolts, take all the screws off the front plate of the pump.
  • The second plate houses the valves.  Check every valve to make sure there is no debris causing them to stay open.  
  • Clean the valve by removing the debris 
  • Re-attach the front plate


NOTE: It is important to use a torque wrench when assembling the pump plate onto the body.  Torque settings are 18FT LBS


Old Pump?

 

When was the last time any maintenance was done to the pump? Replacing the o-rings and valves usually takes care of the majority of the issues that customers come across. If a new valve and seal kit did not do the trick.  It maybe time for a new pump or you can contact Sonny's customer service and ask us about our Wanner Loaner Program. 


Things to look out for:

Worn pump valves
• Airlock in outlet system
• Oil level low
• Wrong weight of oil for cold operating temperatures (change
to lighter weight)
• Cavitation
• Air in suction line
• Restriction in inlet/suction line
• Hydraulic cells not primed after changing diaphragm
• Foreign material in inlet or outlet valve
• Damaged diaphragm
• Fatigued or broken valve spring
• Broken piston return spring (inside hydraulic end)


If you have any further issues or questions please feel free to contact your Sonny's Technical Support Team at: SonnysSupport@SonnysDirect.com